Design constraints
The design brief called for a mix of private offices, small huddle rooms, larger conference rooms, cafeteria and lounge areas. These are the project’s stated planning needs, not measured post-occupancy outcomes.
Mississauga, Ontario, Canada
The Fortune 500 company relocated to Mississauga, Ontario, seeking a contemporary workplace with a range of settings, from private offices and small huddle rooms to larger conference rooms, a cafeteria and lounge areas. Sasaki led the design across two buildings. The project used moodwall P3 and P4, with single- and double-glazed configurations considered for different space requirements.
Rampart worked with the design and construction teams on the glass wall scope. The project record identifies both moodwall P3 and P4 and includes single-glazed special acoustic and double-glazed configurations. The product test ratings are described below without assigning a rating to a specific system.
Specification evidence
The documented brief describes varied workplace settings across two buildings. The evidence below distinguishes project information from product test data.
The design brief called for a mix of private offices, small huddle rooms, larger conference rooms, cafeteria and lounge areas. These are the project’s stated planning needs, not measured post-occupancy outcomes.
The project used moodwall P3 and P4. The record includes special acoustic single glazing and double glazing; it does not confirm which glazing configuration paired with which system.
Sasaki is identified as the design team; CAS Interiors is identified for construction management. The project is in Mississauga, Ontario, and the design covered two buildings. No project area or installed quantity is stated here.
STC 39 for special acoustic single glazing and STC 45 for double glazing are product test ratings, not field measurements from this project. Do not treat them as room-performance guarantees. Results depend on the complete assembly, glass build-up, doors, seals, interfaces and installation. Request the test report for the matching system and configuration.
For a new specification, confirm the required privacy level and room adjacencies, identify the intended glass make-up and door conditions, coordinate perimeter and head/jamb details, and verify that the tested assembly matches the scheduled configuration.
These are current generic technical references, not project as-builts. Confirm the applicable configuration and details for your project.