Design constraints
The centre’s design intent brought together study, meeting and group-work settings, with distinct colour identities. Acoustic privacy was part of the design brief; no measured in-room result is claimed here.
341 Yonge St. Toronto
Ryerson University’s Student Learning Center was planned as a varied learning environment for studying, meeting and exchanging ideas. The architectural concept uses colour and distinct settings, including spaces for student groups and quiet study. Snøhetta Architects is identified as the design team and EllisDon as the general contractor.
The project used moodwall P4 double glass, with a documented product test rating of STC 45. The project context includes custom glass sizing, shapes and colour films. This rating describes a product test and is not a field measurement or a guarantee of room-to-room performance.
Specification evidence
A focused record of the known system and acoustic qualification, with practical checks for applying it to a new design.
The centre’s design intent brought together study, meeting and group-work settings, with distinct colour identities. Acoustic privacy was part of the design brief; no measured in-room result is claimed here.
The project used moodwall P4 double glass. A product test rating of STC 45 is documented for that configuration.
Snøhetta Architects is identified as the design team and EllisDon as general contractor. Custom glass sizing, shapes and colour films are part of the project context. Project area and installed quantities are not presented as verified specifications.
STC 45 is a product test rating, not a field measurement at the learning centre or a room-performance guarantee. Overall results depend on the complete assembly, glass make-up, doors, seals, interfaces and installation. Request the test report and confirm that its tested configuration matches the intended design.
Confirm the intended privacy level and room adjacencies; review glass make-up and door selection together; coordinate seals and perimeter conditions; and verify the tested assembly against the scheduled details before specifying.
These are current generic technical references, not project as-builts. Confirm the applicable configuration and details for your project.